<LOGO>
FM Transmitter Measurement Report
Created: 2026-10-03 16-16-21
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 4/5, 46 dBuV SANDELS
Pilot RDS Phase Difference
4.9 kHz 5.4 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
17 kHz 21 kHz 7461 0,0000
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
-1,0 dBr 2,38 dBr 4,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7, 103.8 MHz -
FM Scope Max at: 21 kHz MIN: 17 kHz % above 76 kHz: 0,0000 Acquired: 2026.10.03 16.15.18 Total samples: 7461 Equivalent time: 0:06:13 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 4,6 dBr MIN: -1,0 dBr AVE: 2,38 dBr % above 12,2 dBr: 0,0 Last value: 3,4 dBr (2026.10.03 16.15.17) 16.02 16.04 16.06 16.08 16.10 16.12 16.14 0 2 4 Pm [dBr]